One of the most common issues I come across when carrying out Legionella risk assessments is surprisingly simple:

There is no written scheme of control in place.

The site may have:

  • A recent risk assessment
  • Some temperature checks
  • Occasional monitoring

…but no clear, structured plan explaining how Legionella risk is actually being managed.

And that’s a problem.


What Is a Written Scheme of Control?

A written scheme of control is a site-specific document that sets out how you manage and control the risk of Legionella within your water systems.

It should clearly define:

  • What control measures are required
  • Who is responsible for each task
  • How often tasks are carried out
  • What the acceptable limits are (e.g. temperatures)
  • What to do if something goes wrong

In simple terms — it’s your plan for staying compliant and keeping people safe.


Why Is It So Important?

Without a written scheme, there is:

  • No clear structure
  • No accountability
  • No consistency

This often leads to:

  • Tasks being missed
  • Monitoring being inconsistent
  • Confusion over responsibilities
  • Increased risk within the system

From a compliance point of view, it also means you are not meeting UK guidance under ACOP L8 and HSG274.


What I Commonly See on Site

In reality, this is what it usually looks like:

  • “We’ve got a risk assessment somewhere…”
  • “Our contractor does the monitoring”
  • “We flush outlets when we remember”

But when you ask for the written scheme — it doesn’t exist.

Or it’s:

  • Generic
  • Outdated
  • Not relevant to the actual system

A written scheme should never be a copy-and-paste document — it needs to reflect your specific building and water systems.


What Should Be Included?

A suitable written scheme of control should cover:

System Overview

A clear description of your water systems, including:

  • Cold water storage
  • Hot water systems
  • Outlets and usage

Control Measures

For example:

  • Temperature monitoring
  • Flushing of infrequently used outlets
  • Cleaning and disinfection
  • TMV servicing
  • Tank inspections

Responsibilities

Who is responsible for:

  • Day-to-day tasks
  • Monitoring
  • Oversight
  • Reviewing the system

Monitoring & Frequency

How often tasks are carried out, such as:

  • Weekly flushing
  • Monthly temperature checks
  • Quarterly inspections

Action Levels

What constitutes a failure, and what action is required:

  • Hot water below 50°C
  • Cold water above 20°C
  • Poor flow or stagnation

Records

What needs to be recorded and retained:

  • Temperature logs
  • Flushing records
  • Maintenance reports

The Risk of Not Having One

Without a written scheme of control, you’re relying on:

  • Memory
  • Assumptions
  • Inconsistent processes

This is where things start to go wrong.

In the event of:

  • A failed audit
  • An incident
  • Or worse — a case of Legionnaires’ disease

…the lack of a written scheme becomes a serious compliance issue.


It’s Not Just Paperwork

A good written scheme isn’t just a document — it’s a practical tool.

The sites that manage Legionella well are the ones where:

  • Everyone knows what needs to be done
  • Tasks are clearly assigned
  • Monitoring is consistent
  • Issues are picked up early

That all starts with having a clear, usable scheme in place.


Final Thoughts

If you have a Legionella risk assessment but no written scheme of control, there’s a gap in your compliance.

It doesn’t need to be complicated — but it does need to be:

  • Clear
  • Site-specific
  • Actively used

If you’re unsure whether your current setup meets requirements, it’s worth reviewing before it becomes a bigger issue.


Need Support?

At Edge Water Hygiene, we help businesses put together practical, easy-to-follow written schemes of control that actually work on site — not just on paper.

If you need help reviewing or creating a written scheme, get in touch.


Leave a Reply